Please ensure Javascript is enabled for purposes of website accessibility
XPL1B Series

XPL1B Series 40W HazLoc LED Linear in 4000K

Ordering information

Specifications

Listings & certifications

Listings & Certifications
  • UL C1D2 (Group A, B, C, D)
  • UL C2D1 (Group E, F, G)
  • UL C3D1
  • UL 844 (Hazardous Location)
  • IP66 Ingress Protection
  • NEMA 3 Enclosure Rating
  • NEMA 4X Enclosure Rating
  • IK08 Impact Rating
  • 5G Vibration Rating (ANSI C136.31)
  • ASTM B117 (1,000 Hours of Salt Spray)
  • CSA C22.2 No 137-M1981
  • IECEx Certified (Ex-nR-IIC-T6-Gc)
  • FCC Class B
  • UL 1598A (Marine Vessels)
  • Wet-Location (UL 1598)
Other Certifications
  • Meets FCC Part 15, Subpart B, Class B standards for conducted and radiated emissions

Features

Construction

  • Heavy duty die-cast copper-free aluminum housing
  • Stainless steel hardware
  • 3/4” NPT threaded conduit wires access ports
  • Weight - 2’: 13.6 lbs ; 4’: 19.1 lbs ; 2’EM: 18.7 lbs ; 4’EM: 22.7 lbs
  • RoHS Compliant
  • Captive bolts on power supply cover
  • RAL 7037 (Dusty Gray) polyester powder coat

Optical System

  • Heavy-duty tempered glass lens creates uniform light distribution and maximizes lumen output
  • Diffused lens optional, consult factory for availability
  • CCT Options: 3000K**, 4000K**, or 5000K
  • CRI: 70
  • **Non-Emergency models only

Electrical

  • Input voltage of 120-277VAC or 347-480VAC**
  • Input frequency of 50/60Hz
  • Power Factor: ≥0.9**
  • Power Factor: ≥0.95*
  • THD <20%
  • 6Kv for 40W and 80W surge protection**
  • Battery Backup Mode*
  • Output Power of 12W*
  • Charge Time of 24 hours*
  • Emergency Run Time of 90 minutes*
  • Reported L70 hours >120,000 Operation Hours @ 50°C**
  • Operating Temperature: -40°F (-40°C) to 122°F (50°C)**
  • C1D2 T3C Class I, Division 2, Group A, B, C, D**
  • C2D1 T4A Class II, Division 1, Groups E, F, G**
  • C3D1 T4A Class III, Division 1**
  • Operating Temperature: 32°F (0°C) to 122°F (50°C)*
  • C2D1 T6 Class II, Division 1, Group E, F, G*
  • C1D2 T4A/T4 Class I, Division 2, Group A, B, C, D*
  • Ambient Operating Humidity of 10%~90% RH** and 5%~95% RH*
  • *Emergency models only
  • **Non-Emergency models only

Installations

  • Prewired with 2’ flying leads
  • Allows wiring without opening power supply cover
  • Integrated 3/4” NPT threaded hub for pendant mount
  • Universal trunnion bracket available, with legacy bolt patern (drill rigs)
  • For installations where power surge may be possible, NICOR recommends installing additional surge protection at the electrical distribution panel

Full Listings

  • Class I, Division 2, Group A, B, C, D
  • Class II, Division 1, Group E, F, G
  • Class III, Division 1
  • UL 844 Hazardous Location
  • UL 924 Emergency Lighting 1
  • UL 1598 Wet Location 2
  • UL 1598A Marine 2
  • IP66 Rated
  • IK08
  • 5G Vibration
  • 1000 hrs Salt Spray
  • CSA C22.2 No. 137-M1981
  • IECEx Ex nR II C T6 Gc
  • RoHS Compliant
  • Meets FCC Part 15, Subpart B, Class B standards for conducted and radiated emissions

Warranty

  • 5-year limited system warranty standard
  • Warranty does not cover product failure due to an overvoltage event (power surge)