Please ensure Javascript is enabled for purposes of website accessibility
XPR1B Series

XPR Series 65W HazLoc LED Area Light in 4000K (Multi-Mount)

Ordering information

Specifications

Listings & certifications

Listings & Certifications
  • UL Certified
  • UL C1D2 (Group A, B, C, D)
  • UL C2D1 (Group E, F, G)
  • UL C2D2 (Group F, G)
  • UL Class 3
  • UL 844 (Hazardous Location)
  • UL 8750 (LED Safety)
  • IP66 Ingress Protection
  • NEMA 3 Enclosure Rating
  • NEMA 4X Enclosure Rating
  • CSA C22.2 No 250.0-8
  • CSA C22.2 No 250.13
  • IECEx Certified
  • RoHS Compliant
  • FCC Class B
  • UL 1598A (Marine Vessels)
  • Wet-Location (UL 1598)
Other Certifications
  • Meets FCC Part 15, Subpart B, Class B standards for conducted and radiated emissions

Features

Construction

  • Die-cast, copper-free aluminum housing
  • Chimney type structure design improves heat dissipation, increasing lifespan
  • Stainless steel hardware
  • Weight - 10.8 lbs
  • 3/4” NPT threaded conduit/wire access port or multi-mount attachment points
  • RoHS Compliant
  • RAL 7037 (Dusty Gray) polyester powder coat

Optical System

  • Tempered glass creates uniform light distribution and maximizes lumen output
  • Diffused lens optional**
  • CCT: 3000K**, 4000K**, or 5000K
  • CRI: 70+
  • **Consult factory for availability

Electrical

  • Input voltage of 100-240/277VAC or 347-480VAC (45W only)**
  • Input frequency of 50/60Hz
  • Power Factor of ≥.95
  • THD <20%
  • 10kA surge protector
  • Reported L70 hours >50,000
  • Ambient Operating Temperature -40°F (-40°C) ~ 131°F (55°C)
  • C1D2 T4A at 131°F (55°C)
  • C2D1 T5 at 131°F (55°C)
  • C2D2 T5 at 131°F (55°C)
  • Ambient Operating Humidity of 10%~90% RH
  • **Consult factory for availability

Installations

  • Available in Multi-Mount or Pendant Mount options
  • Multi-mount stanchion and wall mount accessories available in 25° and 90° options
  • Pendant Mount adjustable trunnion bracket available for ceiling, wall, etc.
  • Pendant Mount uses 3/4” NPT
  • For installations where power surge may be possible, NICOR recommends installing additional surge protection at the electrical distribution panel

Full Listings

  • Class I Division 2, Group A, B, C, D
  • Class II Division 1, Group E,F, G
  • Class II Division 2, Group F, G
  • Class III
  • UL 844 Hazardous Location
  • UL 1598 Wet Locations
  • UL 1598A, Marine
  • UL 8750 LED Safety
  • IP66 Rated
  • CSA C22.2 No. 250.0-08, 250.13
  • IECEx
  • Meets FCC Part 15, Subpart B, Class B standards for conducted and radiated emissions

Warranty

  • 5-year limited system warranty standard
  • Warranty does not cover product failure due to an overvoltage event (power surge)